DOCUMENT VERSION 7.0 | MARCH 2024
SMARTneo-3G
Operating Manual
SMARTneo-2G

Table of Contents

Questions and Answers

  • M
    Mason NguyenSep 23, 2025
    What to do if my LOGICDATA Control Unit shows error E93?
    • K
      Kevin HallSep 23, 2025
      If your LOGICDATA Control Unit displays error E93, it might be due to cascading errors. First, check all plug connections and cables, replacing any defective ones. If the problem persists, inspect the Control Boxes themselves and replace any that are faulty.
  • J
    Jordan LeeAug 25, 2025
    What to do if the LOGICDATA SMARTneo-3G user interface does not work?
    • B
      Barbara PerezAug 25, 2025
      If the user interface isn't working, it could be defective or not properly connected. Ensure that the user interface is correctly connected to the control box. If the problem continues, the user interface likely needs to be replaced.
  • W
    waynelynchAug 25, 2025
    What does error E00 mean on my LOGICDATA SMARTneo-3G?
    • V
      Veronica JonesAug 26, 2025
      Error E00 indicates an internal error has occurred. To resolve this, consult the error code table to find the appropriate response for the specific error code displayed.
  • J
    Jonathan ParkerAug 27, 2025
    Why does my LOGICDATA SMARTneo-3G Control Unit table only move downwards?
    • T
      Teresa WalkerAug 27, 2025
      The table might only be moving downwards because of a power failure during motion or a defective actuator. In the event of a power failure, perform a position reset procedure. If the issue continues, the actuator may need to be replaced.
  • E
    Erin NavarroSep 23, 2025
    What to do if my LOGICDATA Control Unit shows error E7O?
    • F
      farmercameronSep 23, 2025
      If the LOGICDATA Control Unit shows error E7O, it might be because the actuator configuration has been changed. To resolve this, disconnect the Control Boxes from the power supply for about 30 seconds. Then, reconnect them and perform a Reference Drive.
  • E
    emilywilliamsSep 13, 2025
    What does E60 error 'ISP Activated' mean on LOGICDATA SMARTneo-3G Control Unit?
    • S
      Scott CabreraSep 13, 2025
      Error E60 means ISP is activated. Release all keys and wait for the drive back function to complete.
  • E
    erikashawSep 12, 2025
    How do I fix the E55 error 'Sync Error, Motor Group 1' on my LOGICDATA Control Unit?
    • L
      Lynn PittsSep 12, 2025
      To fix the E55 error, remove any excess load from the table and perform a factory reset.
  • M
    Marcus McgeeSep 12, 2025
    What to do if I get E56 error 'Sync Error, Motor Group 2' on LOGICDATA SMARTneo-3G Control Unit?
    • F
      Frank SmithSep 12, 2025
      If you get error E56, remove any excess load from the table and perform a factory reset.
  • K
    Kelly PorterSep 4, 2025
    What does E62 error 'Stop due to power output control' mean on LOGICDATA SMARTneo-3G?
    • B
      Brian FernandezSep 4, 2025
      The E62 error means the system stopped due to power output control. Make sure nothing is blocking the table's movement and that you remove any excess load from it.
  • F
    fwilliamsSep 2, 2025
    What does error E25 'Overcurrent Motor M2' mean on a LOGICDATA SMARTneo-3G Control Unit?
    • J
      Jeffrey McbrideSep 2, 2025
      Error E25 indicates an overcurrent in motor M2. Check that nothing is obstructing the table's movement and remove any excess weight from the table.

LOGICDATA SMARTneo-3G Specifications