Questions and Answers

  • E
    erikashawSep 12, 2025
    How do I fix the E55 error 'Sync Error, Motor Group 1' on my LOGICDATA Control Unit?
    • L
      Lynn PittsSep 12, 2025
      To fix the E55 error, remove any excess load from the table and perform a factory reset.
  • J
    jennifer29Sep 9, 2025
    How to fix E72 error 'Position Error (Middle Switch*)' on LOGICDATA SMARTneo-3G?
    • T
      Taylor PerezSep 10, 2025
      To resolve error E72, disconnect the control box from the mains and wait for at least 20 seconds. Reconnect the system and perform a position reset procedure.
  • J
    Jessica HuertaSep 8, 2025
    What to do if E61 error 'Motor Replaced' appears on LOGICDATA SMARTneo-3G Control Unit?
    • D
      Donna AllenSep 8, 2025
      If error E61 appears, plug in the correct motor and ensure all cables are connected correctly. Perform a factory reset and a position reset procedure.
  • D
    Desiree MoonSep 7, 2025
    What does E37 error 'Plug detected in M2' mean on my LOGICDATA SMARTneo-3G Control Unit?
    • D
      Devin GraySep 7, 2025
      Error E37 indicates a plug is detected in M2. Ensure the correct motor is plugged in and all cables are properly connected. Perform a factory reset followed by a position reset procedure.
  • D
    Danielle GarzaAug 23, 2025
    Why my LOGICDATA SMARTneo-3G table does not move?
    • B
      brian17Aug 23, 2025
      The table might not be moving due to several reasons. Ensure the system is correctly plugged in and the actuator is properly connected to all components. Check for poor plug connections and ensure all plugs are correctly connected. If the issue persists, the actuator or user interface might be defective, requiring replacement.
  • W
    waynegreenSep 5, 2025
    How to fix E70 error 'Motor Configuration Changed' on LOGICDATA Control Unit?
    • O
      Olivia JacksonSep 5, 2025
      To fix error E70, disconnect the control box from the mains. Connect the actuators in the desired setup and perform a factory reset, followed by a position reset procedure.
  • K
    Kelly PorterSep 4, 2025
    What does E62 error 'Stop due to power output control' mean on LOGICDATA SMARTneo-3G?
    • B
      Brian FernandezSep 4, 2025
      The E62 error means the system stopped due to power output control. Make sure nothing is blocking the table's movement and that you remove any excess load from it.
  • A
    Amanda BennettSep 3, 2025
    What to do for E48 error 'Overcurrent Motor Group 1' on LOGICDATA SMARTneo-3G Control Unit?
    • T
      Tyler DiazSep 3, 2025
      If you see error E48, it means there's an overcurrent in motor group 1. Ensure that the table's movement isn't blocked and remove any extra weight from it.
  • F
    fwilliamsSep 2, 2025
    What does error E25 'Overcurrent Motor M2' mean on a LOGICDATA SMARTneo-3G Control Unit?
    • J
      Jeffrey McbrideSep 2, 2025
      Error E25 indicates an overcurrent in motor M2. Check that nothing is obstructing the table's movement and remove any excess weight from the table.
  • M
    Matthew LambertSep 1, 2025
    What does E24 error 'Overcurrent Motor M1' mean for LOGICDATA Control Unit?
    • J
      jennifer47Sep 1, 2025
      The E24 error indicates an overcurrent in motor M1. To address this, check that nothing is blocking the table's range of movement and remove any excess load from the table.