  • W
    William DavisAug 30, 2025
    What causes E65 error 'Overcurrent while driving' on LOGICDATA SMARTneo-3G?
    • M
      Mark PhillipsAug 31, 2025
      The E65 error indicates an overcurrent while driving. Check that nothing is blocking the table's range of movement and remove any excess load from the table.
  • L
    Loretta StephensAug 29, 2025
    How to resolve E13 error 'Defect Channel 2' on LOGICDATA Control Unit?
    • N
      Nicholas LyonsAug 29, 2025
      To resolve error E13, disconnect the control box from the mains. Fix any external short circuits and ensure all cables are connected correctly. Reconnect the system, then operate as normal.
  • R
    Roger RiversAug 28, 2025
    How to fix E12 error 'Defect Channel 1' on LOGICDATA Control Unit?
    • C
      Corey LongAug 28, 2025
      To fix error E12, disconnect the control box from the mains. Then, fix any external short circuits and ensure all cables are correctly connected. Finally, reconnect the system and operate as normal.
  • D
    David WuAug 27, 2025
    What does 'Hot' mean on my LOGICDATA SMARTneo-3G display and how to fix it?
    • A
      Alexander ShepherdAug 27, 2025
      If the display shows 'Hot', it indicates that the duty cycle might be exceeded, causing components to overheat. Allow the components to cool down before resuming operation.
  • J
    Jonathan ParkerAug 27, 2025
    Why does my LOGICDATA SMARTneo-3G Control Unit table only move downwards?
    • T
      Teresa WalkerAug 27, 2025
      The table might only be moving downwards because of a power failure during motion or a defective actuator. In the event of a power failure, perform a position reset procedure. If the issue continues, the actuator may need to be replaced.
  • W
    waynelynchAug 25, 2025
    What does error E00 mean on my LOGICDATA SMARTneo-3G?
    • V
      Veronica JonesAug 26, 2025
      Error E00 indicates an internal error has occurred. To resolve this, consult the error code table to find the appropriate response for the specific error code displayed.
  • J
    Jordan LeeAug 25, 2025
    What to do if the LOGICDATA SMARTneo-3G user interface does not work?
    • B
      Barbara PerezAug 25, 2025
      If the user interface isn't working, it could be defective or not properly connected. Ensure that the user interface is correctly connected to the control box. If the problem continues, the user interface likely needs to be replaced.