5.1 Fuses - replacement
There are 5 fuses in the electrical circuit, located behind
the plate with this pictogram.
A) 40 Amp fuse (only when optional extras)
B) 100 Amp fuse for lifting motor
C) 100 Amp fuse for driving motor
D) 10 Amp fuse in the control current circuit
E) 20 Amp fuse for built-in charger
Replacement:
The old fuse is to be removed and replaced
by a new one of the same size.
Do not use a bigger fuse, as the fuse works
as protection of the electric circuit.
Find out why fuses blow!
5.2 Wiring connections
Many operational disturbances are caused by bad connections in
the electrical circuit. Make sure that the connections are in order.
Check connections regularly for damage at insulating caps or bad connections at
plugs etc.
Verdigris must be removed from cable plugs. Keep all screw/nut connections tight.