Chapter III Maintenance
- 6 -
3-1 Maintenance schedule
Favorable maintenance is the best guarantee to
achieve the safe, economical and zero fault operation. In
addition, it also contributes to the environmental
protection. When operating in hot or dusty environment,
the frequency of some maintenance shall be increased as
specified in notes below the table.
The data of maintenance and operation shall be
recorded. Maintenance records will help you to conduct
periodic maintenance and provide evidence for your
warranty requirement.
Accidental starting of the generator unit
during maintenance may cause severe personal injury
or death. The spark plug wire must be disconnected
prior to maintenance.
The generator unit of high temperature
may cause severe scald. Maintenance or repair must
be conducted after the generator unit is completely
cooled down.
Periodic Maintenance Schedule
Periodic Maintenance Schedule
Time
of Use
20 H or the First
Month of Initial
Use (3)
50 H or
Every 3
Months (3)
100 H or
Every 6
Months (3)
300 H or
Every Year (3)
Engine oil
Check the
oil level
Replaceme
nt
Air filter
Check
Clear
○(1)
Fuel filter
Clear
Spark canceller
Clear
Spark plug
Clear
Replacement
Valve clearance
Readjustme
nt
○(2)
Cylinder head
Wash
Every 500 h (2)
Fuel tank & strainer
Wash
Every 2 years (2)
Oil pipe
Replaceme
nt
Every 2 years (2)
(1) Maintenance intervals shall be shortened when it is used in a place full of dusts.
(2) These maintenance items shall be conducted with supports from LONCIN franchised dealers.
(3) Under circumstances of frequent use, long-term use can only be guaranteed through maintenance with
correct intervals specified above.