Chapter IV Disassembly & Repair
- 17 -
4-1-6 No alternating current output voltage
4-1-7 No direct-current output voltage
(Refer to Section 4-5-4)
(Refer to Section 4-5-5)
(Check and adjust)
(Check if the socket is burned; if yes, replace it
with a new one)
No alternating
current
output
voltage
Abnormal engine speed
Fault of stator winding coil
Fault of output socket
Fault of converter
(Replace motor part)
No
direct-current
output
voltage
DC winding short-circuit or open-circuit
(Refer to Section 4-5-5)
Converter fault
(Reinsert it; refer to Section 4-5-5)
Rectifier bridge wiring loose or fault
跳闸