CHAPTER VI COMMON FAULTS AND TROUBLESHOOTING
69
6.1 COMMON TROUBLE-SHOOTING
6.1.1 DURING THE OPERATION, SOME TROUBE-SHOUTING ARE AS THE
FOLLOWING TABLE.(TABLE 10)
TABLE 10
Fault Characteristics
Fault causes Trouble-shooting
Electrical System
When the engine is
running, even if at an
high speed, the
voltage value flashes
Alternator fault
Circuit fault
Replace
Inspect and repair
The sound of
generator is abnormal
Alternator fault Replace
It can not start when
the key turn to "power
on" position.
Circuit fault
Not enough power
Main fuse fault
Inspect and repair
Charge
Replace
The starter-gear works
off and on when
engine is start.
No power Charge
Pressure alarm lamp
of engine oil do not
light when stopping
the engine.
Bulb fault
Pressure sensor fault
Replace
Replace
Hydraulic system
There is abnormal
sound of pump.
No oil in the oil tank
Pump fault
Hydraulic oil not suitable
for surroundings temperature
Fuel
Inspect, then repair or
replace
Replace oil
The equipment run at
the low speed only.
Pump fault
The max. pressure setting
of valve is not correct or due to
impurity close the valve.
The air filter is jammed
Inspect, then repair or
replace
Restart or replace
Clean away the dust and
Replace it.
Drive system