EasyManua.ls Logo

Lotus Evora - Refrigerant Pipework Fixing Torques; Refrigerant Pipework O Rings

Lotus Evora
370 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 11
Lotus Service Notes Section PN
Key Description Qty Thread Pitch Torque
1 Compressor to engine 4 M8 25 Nm
2 A.C. hoses to compressor 2 M6 9 Nm
3 Sill pipe to comp. hose, high pressure 1 3/4 - 16 UNF 1.6 25-30 Nm
4 Sill pipe to comp. hose, low pressure 1 1 1/16 - 14 UNS 1.8 35-40 Nm
5 Sill pipe to condenser pipe 1 3/4 - 16 UNF 1.6 25-30 Nm
6 Receiver-drier connections 2 5/8 - 18 UNF 1.4 25-30 Nm
7 Evaporator pipe to receiver-drier 1 5/8 - 18 UNF 1.4 20-25 Nm
8 Trinary switch to pipe 1 3/8 - 24 UNF 10-13 Nm
9 Clamp plate, pipes to cond & exp valve 1 M6 1.0 9 Nm
10 Clamp plate, expansion valve to evap 1 M5 0.8 6 Nm
11 Evaporator to sill pipe 1 1 1/16 - 14 UNS 1.8 35-40 Nm
# Use refrigeration oil only, smear on “O” rings and threads prior to assembly
(Gloves should be worn when handling refrigeration oil - see data sheet)
Key Description Diameter Part Number
A Suction line to compressor. Condenser connections 16 mm A120P6002H
B High pressure line to compressor 13 mm A120P6001H
C Suction pipe to sill pipe and expansion valve 19 mm A082P6081F
D High pressure line to sill pipe 12 mm A082P6079F
E Receiver-drier connections and expansion valve inlet 9 mm A082P6078F
Refrigerant Pipework Fixing Torques
Refrigerant Pipework 'O' Rings
A E6 p115
9
C11
E C D5
10 9 D3 C4
E C
B1
A2

Table of Contents