Chapter 7. Usage of Various Functions
7-38
SV(Target) (for G7F-RD2A)
- 1300(60),1350(70),1400(80),1500(100)
PV(Current) conversion value of the RTD module’s channel 0 (Expansion module #2’s channel 0: %MW4104)
Set Proportional Gain, Derivational Time, Integral Time
BIAS: 0 (input proper value to use P control only)
Mode Command Set: select the related items Derivative, Integral, Proportional
(select PWM when it is needed)
PWM Contact: set the contact when the PWM output is selected
SV Ramp: 500 (when SV converted‘500*0.5 sec = 25 sec’)
ΔMV : 4000 (delta MV function is not used)
PID Algorithm: Velocity
Value: