34
Attribute
ID
Access
Attribute
Name
Range
Definition
Reverse
1
Operating in normal
direction
9
Get
Drive
Ready
0
Being reset or tripped
1
Normal condition for
Inverter operation
10
Get
Drive
Fault
0
Presently not tripped
1
Presently being tripped.
12
Get / Set
Drive
Fault
Reset
0
Trip Reset after a trip.
Reset can be done only
when TRUE is inputted in
FALSE status (Note2).
1
13
Get
Drive
Fault
Code
See the Drive Fault Code
Table below (Note2).
14
Get
Control
From
Net.
0
Provide operation
reference through a source
other than DeviceNet
communication.
1
Provide operation
reference through
DeviceNet communication
source.
(Note1) Drive Run Command
Inverter operation using Forward Run Cmd. and Reverse Run Cmd.

Table of Contents