iS7 Ethernet Option Manual
21
70,71,110,111 0,1Byte 비트에 대한 Data 설명입니다.
Name
Description
Related Attribute
Class
Attr. ID
Faulted
Inverter Error
0x29
10
Warning
Not Supported
0x29
11
Running1
Motor is running Forward
0x29
7
Running2
Motor is running Reverse
0x29
8
Ready
Motor is ready to running
0x29
9
Ctrl From Net
Run/Stop control
0x29
15
Ref From Net
Speed control
0x2A
29
At Reference
Reach at reference Speed
0x2A
3
Drive State
Current Motor State
0x29
6
Speed Actual
Speed Command
0x2A
7
Output Instance
PLC혹은 Client기기가 인버터에 지령을 주기적으로 보내는 Data입니다.
Instance
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
20
0
Fault
Reset
Run
Fwd
1
0
2
Speed Reference (Low Byte) RPM unit
3
Speed Reference (High Byte) RPM unit
21
0
NetRef
(note 2)
NetCtrl
(note2)
Fault
Reset
Run
Rev
Run
Fwd
1
0
2
Speed Reference (Low Byte) RPM unit
3
Speed Reference (High Byte) RPM unit
100
0
Fault
Reset
Run
Fwd
1
0
2
Speed Reference (Low Byte) Hz unit
3
Speed Reference (High Byte) Hz unit