EasyManua.ls Logo

LS SV-iS7 Series - Page 67

LS SV-iS7 Series
77 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
iS7 Ethernet Option Manual
24
Instance
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
6
Control Parameter - 4 data (Low Byte)
7
Control Parameter - 4 data (Hi Byte)
8
Control Parameter - 5 data (Low Byte)
9
Control Parameter - 5 data (Hi Byte)
10
Control Parameter - 6 data (Low Byte)
11
Control Parameter - 6 data (Hi Byte)
12
Control Parameter - 7 data (Low Byte)
13
Control Parameter - 7 data (Hi Byte)
14
Control Parameter - 8 data (Low Byte)
15
Control Parameter - 8 data (Hi Byte)
20,21,100,101 0Byte 비트에 대한 Data 설명입니다.
Name
Description
Related Attribute
Class
Attr. ID
Run Fwd(1)
Forward Run Command
0x29
3
Run Rev(1)
Reverse Run Command
0x29
4
Fault reset(1)
Fault Reset Command
0x29
12
NetRef(2)
Not used
0x2A
4
NetCtrl(2)
Not used
0x29
5
Speed Reference
Speed Command
0x2A
8
(1) Control Supervisor Object (Class 0x29) Drive Run부분과 Fault부분을
조하기 바랍니다.
(2) Reference Control Run/Strop Control 설정은 LCD Control Pannel
통해서만 가능하게 되어 있습니다. 따라 Instance 21 101에서 (NetRef,
NetCtrl) 사용되지 않습니다.
(3) Explicit Message
주기 통신으로 인버터 혹인 EtherNet/IP Attribute 값을 읽거나 사용
하는 통신 방법입니다.
Originator Target사이에 Connection 하지 않고 Data 주고 받는 UCMM방법
Class 3 Connection 맺고 Data 주기적으로 주고 받는 방법이 있습니다.