Thank you for purchasing LS Variable Frequency Drives!
SAFETY INSTRUCTIONS
To prevent injury and property damage, follow these
instructions. Incorrect operation due to ignoring instructions
will cause harm or damage. The seriousness of which is
indicated by the following symbols.
DANGER
WARNING
CAUTION
This symbol indicates the possibility of
death or serious injury
This symbol indicates the possibility of
This symbol indicates the instant death or
serious injury if you don’t follow instructions
The meaning of each symbol in this manual and on your equipment is as
follows
.
This is the safety alert symbol.
Read and follow instructions carefully to avoid dangerous situation.
This symbol alerts the user to the presence of “dangerous voltage”
inside the product that might cause harm or electric shock.
After reading this manual, keep it in the place that the user always can
contact easily.
This manual should be given to the person who actually uses the products
and is responsible for their maintenance.

Questions and Answers

LS SV150iS5-4 Specifications

General IconGeneral
ModelSV150iS5-4
Rated Output Current150A
Applicable Motor Capacity75kW
Braking ResistorBuilt-in
Cooling MethodForced Air Cooling
Control MethodV/F control, Sensorless vector control
Communication PortsRS485
Programming LanguageLadder Diagram
Protection FunctionsOvercurrent, Overvoltage, Overheating
Frequency0.1-400Hz
Ambient Temperature-10°C to +40°C
Storage Temperature-20 to 65°C
Humidity5 ~ 95% RH, non-condensing
Rated Input Voltage380 ~ 480V AC, 50/60Hz
Number of Inputs8 Digital Inputs, 2 Analog Inputs

Summary

SAFETY INSTRUCTIONS

DANGER

This symbol indicates the instant death or serious injury if you don’t follow instructions.

WARNING

This symbol indicates the possibility of death or serious injury.

CAUTION

This symbol indicates the possibility of injury or damage to property.

CHAPTER 1 - INSTALLATION

CHAPTER 2 - OPERATION

CHAPTER 5 - PARAMETER LIST

5.1 Drive Group [DRV]

Lists parameters for Command Frequency, Torque, Output Current, Motor Speed, and Fault Display.

5.2 Function 1 Group [FU1]

Lists parameters related to Run Prevention, Acceleration/Deceleration Patterns, Stop Mode, and Torque Boost.

5.3 Function 2 Group [FU2]

Lists parameters for Fault History, Frequency Jump, Auto-tuning, PID control, and Motor related settings.

5.4 Input;Output Group [I;O]

Lists parameters for analog input signals, multi-function terminals, and output signals.

5.5 External Group [EXT]

Lists parameters for Sub-Board functions, including multi-function inputs, outputs, and analog adjustments.

5.6 Communication Group [COM]

Lists parameters for communication options like F-Net, RS-485, and Modbus-RTU.

5.7 Application Group [APP]

Lists parameters for application-specific functions like Traverse, MMC, Draw, and Auto Change.

CHAPTER 6 - PARAMETER DESCRIPTION

6.1 Drive group [DRV]

Detailed descriptions of DRV group parameters, including frequency settings, acceleration/deceleration, and fault displays.

6.2 Function 1 Group [FU1]

Detailed descriptions of FU1 group parameters, covering run prevention, acceleration patterns, stop modes, and torque boost.

6.3 Function 2 Group [FU2]

Detailed descriptions of FU2 group parameters, including fault history, frequency jump, auto-tuning, and PID control.

6.4 Input;Output Group [I;O]

Detailed descriptions of I/O group parameters for analog inputs, multi-function terminals, and outputs.

CHAPTER 7 - OPTIONS

CHAPTER 8 - TROUBLESHOOTING & MAINTENANCE

8.1 Fault Display

Lists inverter faults, their protective functions, keypad display, and descriptions.

8.2 Fault Remedy

Provides causes and remedies for various inverter protective functions and faults.

8.3 Troubleshooting

Lists common operational issues and their corresponding check points for diagnosis.