7. Function List
7-18
LED
display
Parameter
name
Min/Max
range
Description
Factory
defaults
Adjustable
during run
Page
16
Frequency
decrease
command
(DOWN)
17 3-wire operation
18 External trip: A Contact (EtA)
19 External trip: B Contact (EtB)
20 -
21
Exchange between PID
operation and V/F operation
22
Exchange between option
and Inverter
23 Analog Hold
24 Accel/Decel Disable
I25 [Input terminal
status display]
-
BIT4 BIT3 BIT2 BIT1 BIT0
- -
P5 P4 P3 P2 P1
I26 [Output
terminal
status display]
-
- BIT1 BIT0
-
-
-
30AC MO
I27
[Filtering time
constant for
Multi-function
Input terminal]
2/50 If the value is set higher, the
response of the Input terminal is
getting slower.
15 O
I30 [Multi-Step
frequency 4]
0/400
[Hz]
It cannot be set greater than
F21 [Max frequency].
30.0 O
I31 [Multi-Step
frequency 5]
25.0 O
I32 [Multi-Step
frequency 6]
20.0 O
I33 [Multi-Step
frequency 7]
15.0 O
I34 [Multi-Accel
time 1]
0/6000
[sec]
-
3.0 O
I35 [Multi-Decel
time 1]
3.0
I36 [Multi-Accel
time 2]
4.0