Installation
16
Wall-Mounting a 5-Slot Carrier and Modules
Install the 5-Slot Carrier within 5 feet (1.5 meters) of a properly grounded wall
outlet (not controlled by a switch) and the network interface jacks. In addition,
when you mount the carrier on the wall, leave at least 1 foot (0.3 meter) of
clearance at the top and sides, and two feet (0.6 meter) at the front and bottom to
ensure proper ventilation.
NOTE:
The location of each module within the carrier is important; place them as
instructed in the following procedure.
Use the following procedure to wall-mount the carrier and modules:
1 a. Using the enclosed template,
mark the screw locations on
the wall.
b. If you are mounting the carrier
on plywood, start four #12
screws supplied with the
carrier leaving the screw
heads extending
approximately 1/4 inch (0.64
cm) from the wall. If you are
mounting on drywall, use wall
anchors, which must be
purchased separately.
2 Before installing any modules,
make sure the clear, plastic
protector has been removed from
the connector area on the rear of
each module. To remove the
protector, grasp the tabs on the
ends of the protector and lift.
IMPORTANT:
308EC and 206 modules must be
to the left of any 200 and 400
modules.
1
4
"