EasyManua.ls Logo

Lucent Technologies PARTNER Advanced Communications System - Page 440

Lucent Technologies PARTNER Advanced Communications System
484 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
A-5
Requirements for
Out-of-
Building Installations
● Installation of a telephone or other standard (tip/ring) device in another building
requires the following In-Range-Out-Of-Building (IROB) protectors to protect the
control unit and device from electrical surges:
— System phone: two Lucent Technologies IROB protectors
— Standard phone: two Lucent Technologies IROB protector plus one carbon block
protector
● Installation of a Contact Closure Adjunct controlled device outside the building
requires a Lucent Technologies 146G Surge Protector-SCL/8 to protect the control
unit from electrical surges
Wiring
● System phones: Lucent Technologies SYSTIMAX® Bulk Nonplenum (DIW) cable,
Lucent Technologies SYSTIMAX Bulk Plenum (HALAR/HALAR) cable, or at least
2-pair (4-wire) star ("home run" not "loop")
● Other standard telecommunications equipment (single-line phones, fax machines,
answering machines, etc.): 1-pair (2-wire) mounting cords (Lucent Technologies
D2R mounting cords recommended)
● Bridging adapter: Lucent Technologies 267F2
● Range: 1,000 feet (305 meters) for system phones; 3,000 feet (915 meters) for
standard devices
Safety Requirements
● U.S.: Meets UL 1459 Issue 2
— Class 2 power standards:
UL 1012 Standard for Safety – Power Supplies
UL 1310 Standard for Safety – Direct Plug-in Transformers
UL 1585 Standard for Safety – Class 2 and Class 3 Transformers
● Canada: Meets CSA C22.2, No. 0.7-M1985
● All other countries: Meets IEC950 Second Edition and EN60950 Second Edition

Table of Contents

Other manuals for Lucent Technologies PARTNER Advanced Communications System

Related product manuals