9-41
944E-42
Electrical System
281 1347 7 Amber Fuel Pump
Pressurizing
Assembly #1
High Fuel Pressure Solenoid Valve #1 -
Mechanical System Not Responding Properly
or Out of Adjustment
284 1043 4 Amber Internal Sensor
Voltage Supply
Engine Speed/Position Sensor (Crankshaft)
Supply Voltage Circuit - Voltage Below Normal,
or Shorted to Low Source
285 639 9 Amber SAE J1939 Datalink SAE J1939 Multiplexing PGN Timeout Error -
Abnormal Update Rate
286 639 13 Amber SAE J1939 Datalink SAE J1939 Multiplexing Configuration Error-
Out of Calibration
287 91 19 Red Accelerator Pedal
Position
SAE J1939 Multiplexing Accelerator Pedal or
Lever Sensor System Error - Received Network
Data In Error
288 974 19 Red Remote Accelerator SAE J1939 Multiplexing Remote Accelerator
Pedal or Lever Data Error - Received Network
Data In Error
292 441 14 Red Auxiliary
Temperature 1
Auxiliary Temperature Sensor Input 1 - Special
Instructions
293 441 3 Amber OEM Temperature Auxiliary Temperature Sensor Input #1 Circuit -
Voltage Above Normal, or Shorted to High
Source
294 441 4 Amber OEM Temperature Auxiliary Temperature Sensor Input #1 Circuit -
Voltage Below Normal, or Shorted to Low
Source
295 108 2 Amber Barometric Pressure Barometric Pressure Sensor Circuit - Data
Erratic, Intermittent, or Incorrect
296 1388 14 Red Auxiliary Pressure Auxiliary Pressure Sensor Input 1 - Special
Instructions
297 1388 3 Amber Auxiliary Pressure Auxiliary Pressure Sensor Input #2 Circuit -
Voltage Above Normal, or Shorted to High
Source
298 1388 4 Amber Auxiliary Pressure Auxiliary Pressure Sensor Input #2 Circuit -
Voltage Below Normal, or Shorted to Low
Source
319 251 2 Maint Real Time Clock
Power
Real Time Clock Power Interrupt - Data Erratic,
Intermittent, or Incorrect
322 651 5 Amber Injector Cylinder #01 Injector Solenoid Cylinder #1 Circuit - Current
Below Normal, or Open Circuit
323 655 5 Amber Injector Cylinder #05 Injector Solenoid Cylinder #5 Circuit - Current
Below Normal, or Open Circuit
Fault