MANUAL
Series 12
ISR 12-LO IGAR 12-LO IMPAC Pyrometer

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the LumaSense technologies IGAR 12-LO and is the answer not in the manual?

LumaSense technologies IGAR 12-LO Specifications

General IconGeneral
Resolution0.1°C
Storage Temperature-20°C to 70°C
Protection RatingIP65
Accuracywhichever is greater
Emissivity Adjustment0.10 to 1.00 adjustable
OutputRS-485
Emissivity0.10 to 1.00 adjustable

Summary

General

Information about the user manual

Covers manual structure, including legends and terminology for clarity.

Safety

Provides essential safety information, including laser warnings and general cautions.

Limit of liability and warranty

Outlines the company's liability limitations and warranty terms for the instrument.

Unpacking the Instrument

Instructions for inspecting the instrument upon delivery and handling potential damage.

Service Request, Repair, or Support

Details how to contact technical support for issues and the process for service requests.

Shipments to LumaSense for Repair

Provides instructions for shipping instruments to LumaSense for repair, including RMA requirements.

Transport, packaging, storage

Guidelines for safely transporting, packaging, and storing the pyrometer to prevent damage.

Disposal / decommissioning

Instructions for the proper disposal of inoperable pyrometers according to regulations.

Introduction

Appropriate use

Describes the intended applications and benefits of the ISR 12-LO and IGAR 12-LO pyrometers.

Scope of delivery

Lists the components included with the pyrometer upon purchase.

Technical data

Presents detailed technical specifications and operational parameters of the pyrometer.

Dimensions

Provides detailed dimensional drawings and specifications for the pyrometer housing and optical heads.

Physical User Interface

Identifies and explains the components of the pyrometer's physical user interface and housing.

Accessories (Optional)

Overviews optional accessories that enhance the installation and functionality of the pyrometer.

Controls and Connections

Electrical Installation

Instructions for safely connecting the pyrometer to a power source, considering EMV requirements.

Pin assignment of the male socket on the back of the pyrometer

Details the pin configuration of the pyrometer's connector for various functions.

Connector pin J

Explains the multiple functions and applications of connector pin J on the pyrometer.

Connecting the pyrometer to a PC

Guides on establishing a connection between the pyrometer and a PC for data transfer and control.

Connecting to RS232 interface

Specific instructions for connecting the pyrometer to a PC using the RS232 serial interface.

Connecting to RS485 interface / baudrate

Details how to connect the pyrometer via RS485 interface and configure baud rates for bus systems.

Connection of additional analyzing devices

Explains how to connect external devices like digital displays or controllers to the pyrometer.

Wait time tw

Describes setting a wait time for RS485 connections to ensure data transfer reliability.

Mechanical Installation

Provides instructions and considerations for the physical installation of the pyrometer and its components.

Pyrometer

Details the mounting procedures and drill hole locations for the pyrometer converter unit.

Fiber optic

Instructions for connecting and handling the fiber optic cable, including color marking and bending radius.

Optical head

Information on the optical heads, their types, and connection methods to the pyrometer.

Optical head

Discusses the different types of optical heads available and their suitability for various applications.

Spot size data (measuring distance from the front of the lens)

Provides data on spot sizes for different optical heads at various measuring distances.

Adjusting the required measuring distance with optical head I or II, fixed adjusted

Steps for setting the correct measuring distance for fixed adjusted optical heads.

Adjusting the required measuring distance with optical head II, focusable

Instructions on adjusting the measuring distance for focusable optical heads for optimal focus.

Laser targeting light

Explains the function and usage of the laser targeting light for alignment and safety precautions.

Settings / Parameter Descriptions

Factory settings

Lists the default parameter values configured at the factory for the pyrometer.

Instrument settings

Describes how to adjust and configure various instrument settings for optimal performance.

Key panel operation

Details the function of each key on the pyrometer's control panel for parameter adjustment.

Special indications

Explains special display codes and their meanings, such as warm-up or overflow conditions.

Basic range

Explains the automatic display of the pyrometer's total measuring range.

Material

How to set and manage material properties, including emissivity, for accurate measurements.

Temperature display in °C or °F

Instructions on selecting the preferred temperature unit (°C or °F) for display.

Emissivity ɛ / emissivity slope K

Explains emissivity settings for mono mode and emissivity slope for ratio mode measurements.

Response time / exposure time (t90)

Details the response time setting which affects how quickly the pyrometer reaches a stable temperature reading.

Clear time of the maximum value storage (tCL)

Explains settings for clearing maximum value storage, including Off, Extern, Auto, and Hold modes.

Operating mode

Describes the different operating modes: mono, ratio, and metal mode, and their applications.

Switch-off level (OFF / %)

Setting to avoid errors caused by low signal levels, adjustable from 2% to 50%.

Analog Output

How to select the analog output signal (0-20 mA or 4-20 mA) based on connected instruments.

Setting of subrange (from / to)

Allows setting a specific subrange within the basic measuring range for analog output.

Address

Instructions for assigning unique addresses for RS485 communication with multiple pyrometers.

Baud rate (kBaud)

Configuration of the serial interface transmission rate (baud rate) based on cable length.

Software InfraWin

Connecting the pyrometer to a PC

Guidance on connecting the pyrometer to a PC for operation with the InfraWin software.

Installation

Steps for installing the InfraWin software from a CD or downloaded file.

Program start

Instructions on launching the InfraWin software and selecting the initial language.

Maintenance

Safety

Safety precautions to be observed before performing any maintenance on the pyrometer.

Service

Maintenance recommendations, primarily focusing on keeping the lens clean.

Changing of optics

Instructions on how to change the optical heads and when replacement might be necessary.

Data format UPP (Universal Pyrometer Protocol)

Reference numbers

Reference numbers instrument

Information on how to order pyrometers and their optional configurations.

Reference numbers accessories

Lists part numbers and descriptions for various accessories available for the pyrometer.

Troubleshooting

Related product manuals