4-20
CDA3000 Operation Manual
4 Commissioning
CARD
MENU
Read from/write to SMARTCARD:
In this menu inverter settings can be saved to the S
MARTCARD and
transferred to other inverter modules.
In every storage operation all parameters are always saved to the
S
MARTCARD. For read operations, either all parameters or only
parameters from one subject area (per read operation) can be
read-in.
For additional information on operation with the KEYPAD refer to the
KEYPAD KP200 Operation Manual.
Function Meaning
READ > ALL Read all parameters from SMARTCARD
READ > _27RS
Read parameter from subject area,
e.g. _27RS (reference structure)
WRITE Store all parameters on the SMARTCARD
LOCK Write-protect the SMARTCARD
UNLOCK Cancel the write protection