CDD3000-HF Operation Manual
2-7
2  Mechanical installation
DE
EN
FR
IT
ES
FR
1
2
3
4
5
A
 
 
Note the following points: 
• Cooling can be attained either by a sufficiently large 
backing plate (see Table 2.3) or by an additional cooler. 
The cooler must be mounted centrally behind the 
hottest area (1) of the device. See also “Project 
planning notes, “Cold plate”” in Appendix A.3.
• The temperature on the rear panel of the drive 
controller for highspeed drives must not exceed 85.0 °C. At a 
temperature > 85 °C the device shuts down automatically. It can 
only be restarted when it has cooled.
• Required evenness of contact surface = 0.05 mm, maximum 
roughness of contact surface = roughness factor 6.3
(1)
Size
Device rated
power
drive controller for 
highspeed drives
P
V
 [W]
at  4/ 
8-16 kHz
R
thK
 
3)
[K/W]
Backing plate (unvarnished 
steel min. cooling area
Ambient 
temperature
BG1
1.0 kVA CDD32.003-HF,Cx.x 49 / 52 W 0.05 None 45°C
1.6 kVA
CDD32.004-HF,Cx.x 63 / 70 W 0.05 650x100mm = 0.065m²
45°C
1)
, 40°C
2)
BG2
2.2 kVA CDD32.006-HF,Cx.x 90 / 97 W 0.05 650x460mm = 0.3m²
45°C
1)
, 40°C
2)
2.8 kVA CDD32.008-HF,Cx.x 110 / 120 W 0.05 650x460mm = 0.3m²
45°C
1)
, 40°C
2)
1.5 kVA CDD34.003-HF,Cx.x  70 / 85 W 0.05 None
45°C
1)
, 40°C
2)
2.8 kVA CDD34.005-HF,Cx.x 95 / 127 W 0.05 650x460mm = 0.3m²
45°C
1)
, 40°C
2)
3.9 kVA CDD34.006-HF,Cx.x 121 / 163 W 0.05
An additional cooler is required to supply 
adequate cooling. 
For project planning notes see Appendix A.3.
BG3
5.4 kVA
CDD34.008-HF,Cx.x 150 / 177 W 0.03
6.9 kVA CDD34.010-HF,Cx.x 187 / 222 W 0.03
BG4
9.7 kVA
CDD34.014-HF,Cx.x 225 / 283 W 0.02
11.8 kVA CDD34.017-HF,Cx.x 270 / 340 W 0.02
BG5
16.6 kVA
CDD34.024-HF,Cx.x 330 / 415 W 0.015
22.2 kVA CDD34.032-HF,Cx.x 415 / 525 W 0.015
1) With a power stage clock frequency of 4 kHz
2) With a power stage clock frequency of 8/12/16 kHz
3) Thermal resistance between active cooling area and cooler
Table 2.3 Required cooling with cold plate
Note the following points: 
• The backing plate must be grounded over a large area.
• The best result for effective EMC installation is attained with a 
chromated or galvanized backing plate. If backing plates are 
varnished, the coating must be removed in the area of the contact 
surface!