EasyManua.ls Logo

Lust CDD34.003-HF - Wall Mounting

Default Icon
100 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CDD3000-HF Operation Manual
2-3
2 Mechanical installation
DE
EN
FR
IT
ES
FR
1
2
3
4
5
A
2.3 Wall mounting
Figure 2.1 Mounting clearances (see Table 2.1)
Step Action Comment
1
Mark out the position of the tapped holes
on the backing plate.
Cut a tap for each fixing screw in the
backing plate.
Dimensional drawings/hole
spacing see Table 2.1.
The tapping area will provide
you with good, full-area contact.
2
Mount the drive controller for highspeed
drives vertically on the backing plate.
Pay attention to the mounting
clearances!
The contact surface must be
metallically bright.
3
Mount the other components, such as the
mains filter, line choke etc., on the
backing plate.
Mains filter max. 20 cm below
the drive controller for
highspeed drives
4
Continue with electrical installation in
section 3.
Note the following points:
Air must be able to flow unhindered through the device.
The backing plate must be well grounded.
The best result for effective EMC installation is attained with a
chromated or galvanized backing plate. If backing plates are
varnished, the coating must be removed in the area of the contact
surface!
E
E1
G
F
CM-xxxx
F
UM-xxxx
38.5
60
30
60
With ventilator grille

Related product manuals