EasyManua.ls Logo

Lust CDD34.003-HF - Technical Specifications

Default Icon
100 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
A-2
CDD3000-HF Operation Manual
A.1 Technical data
CDD32.003-HF to CDD34.006-HF
1)
Data referred to output voltage 230 V/400 V
and switching frequency 8 kHz
Designation
Technical data
CDD32.003-HF
CDD32.004-HF
CDD32.006-HF
CDD32.008-HF
CDD34.003-HF
CDD34.005-HF
CDD34.006-HF
Output, motor end
1)
Device rated power 1.0 kVA 1.6 kVA 2.2 kVA 2.8 kVA 1.5 kVA 2.8 kVA 3.9 kVA
voltage 3 x 0 ... 230 V 3 x 0 ... 400/460 V
Continuous current (RMS) (I
N
)
2.4 A 4.0 A 5.5 A 7.1 A 2.2 A 4.1 A 5.7 A
Peak current 1.8 x I
N
for 30 s
4.3 A 7.2 A 9.9 A 12.8 A 4.0 A 7.4 A 10.3 A
Rotating field frequency 0 ... 1600 Hz
Switching frequency of power stage 4, 8, 12, 16 kHz
Input, mains side
Mains voltage
1 x 230 V
-20 % +15 %
3 x 400 V / 3 x 460 V
-25 % +10 %
Current (with line choke) 4.4 A 7.3 A 10.0 A 12.9 A 2.3 A 4.3 A 6.0 A
Asymmetry of mains voltage ±3 % max.
Frequency 50/60 Hz ±10 % 50/60 Hz ±10 %
Power loss at 4 / 8.16 kHz [W] 49 / 52 63 / 70 90 / 97 110 / 120 70 / 85 95 / 127 121 / 163
Braking chopper power electronics
Peak braking power with int.
braking resistor (only with version
CDD34 ..., Wx.x, BR)
--
1.6 kW
at 360
Minimum ohmic resistance of an
externally installed braking resistor
100
56 180

Related product manuals