Setting Limits From the Drive
The open and close limits define the travel range of the window treament. Limits can be set
at the Drive, or from a keypad or an IR Remote previously assigned to that Drive. It is recom-
mended that limits be set initially at the Drive.
T = Tap H = Press and Hold
Setting Open Limit
Tap Open Limit button. Green
LED will turn on.
Press and hold either arrow
button to move the Window trea-
ment to desired Open Limit.
Press and hold the Open Limit
button until the Green LED
flashes. Open Limit is stored.
7.1
7.2
7.3
Tap the Close Limit button. The
Green LED will turn on.
Press and hold either arrow
button to move the Window trea-
ment to desired Close Limit.
Press and hold the Close Limit
button until the Green LED
flashes. Close Limit is stored.
7.4
7.5
7.6
Setting Close Limit
T
H
H
H
T
H
H
H
or
or