Conguring the zones
If you need to change the default self-learning behavior, you can congure the zones from the “RControl
Alarm” menu, section “Zones” for the wired zones or “RF Zones” for the wireless zones.
With a double click on the selected zone you can:
•
Change the name of the zone – from section “Zone name”
•
Enable or Disable the zone – from section “Enabled”
•
Set the type of the zone – Instant, Entry/Exit, Follow, Tamper, Panic, Fire etc. – from the menu
“Zon
e type”. Select “Disabled” if the zone will not be used
•
If you have congured a zone as a “Keyswitch zone” you can choose if the alarm panel would be
Armed/Disarmed when this zone is activated. This can be congured from the menu “Keyswitch
action”
•
Congure zone arming type = “Full arm” and “Stay arm” – from menu “Keyswitch arming”.
•
Choose if the siren will be activated when the zone is violated – from section “Notication type”
•
Can choose if every violation of the zone will be reported during the alarm cycle time. You can
congure this from section “Report All During Alarm Cycle”.
If this setting is disabled only the initial violation will be reported and all following activations will not
be reported until the alarm cycle time expires. When the alarm cycle time expires, the zone restore
event will be reported only when the zone is really restored. In addition, even when there was a
restore during the alarm cycle, this restore will not be reported until the expiration of the alar
m cycle
time or until the partition is disarmed.
Zone types
• SMARTEnroll – by default all zones are congured as “Smart Enroll” zones. This means that the
detectors added on these zones will be automatically registered (self-learned) as Instant zones. This
simplies the installation process in the most commonly used scenario, when only instant zones with
no entry/exit times are needed. When a new wired detector is connected to any zone (when the zone
is closed), the zone is registered automatically, and the panel s
tarts monitoring that zone. Zones Z1-
Z7 and Z9-Z16 are self-registered as instant zones and zone Z8 – as a tamper zone (24h Tamper).
When a new zone is being self-registered, the panel reports an event “Added module, Zone N” with
Contact ID E-531.
By default, when a zone is not used it should not be short circuited to the AUX (-). However, if a zone
is already self-registered and will be no longer used, it should be short circuited to the AUX (-) or it
should be disabled, as described in section “Conguring the zones of RC
ontrol Alarm panel”.
If you want to congure dierent zone type, you can do that from the RControl Admin portal > Device
Dashboard > RControl Alarm Settings.