• 24 Hours Gas – When this zone is violated, the panel will immediately latch the alarm output and
communicate to the central station. The siren will follow the Gas alarm pattern and zone number will
be lit.
• 24 Hours Freeze - When this zone is violated, the panel will immediately latch the alarm output and
communicate to the central station. The alarm will sound until the alarm cycle duration expires, or
until a code is entered, or the disarm button of the keyfob is pressed.
• 24 Hours Flood - When this zone is
violated, the panel will immediately latch the alarm output and
communicate to the central station. The alarm will sound until the alarm cycle duration expires, or
until a code is entered, or the disarm button of the keyfob is pressed.
• Keyswitch High Level – When this zone is violated, the system will arm. When this zone is secured,
the system will disarm.
• Keyswitch Low Level – When this zone is violated, the system will disarm. When this zone is
secured, the system will arm.
• Keyswitch High Im
pulse – Momentary change from OFF to ON will alternately arm/disarm the
system.
• Keyswitch Low Impulse - Momentary change from ON to OFF will alternately arm/disarm the
system.