The maximum length of the connecting pipe between the indoor
and outdoor units should be less than 5 meters. A larger length
will affect the efficiency of the air conditioner.
This appliance should not be used by children younger than 8
years old.
Do not let children play with the appliance.
Cleaning and user maintenance work should not be carried out by
children.
The batteries in remote control must be recycled or disposed of
properly.
Disposal of Scrap Batteries: Please discard the batteries as sorted
municipal waste at the accessible collection point.
If the appliance is wired directly to the house line, then it must be
fitted with means for disconnection from the power supply. These
means should have a contact separation in all poles that provide
full disconnection under over voltage category III conditions. These
means must be incorporated in the fixed wiring in accordance with
the wiring rules.
The appliance must be installed in accordance with the national
wiring regulations.
WARNING: RISK OF ELECTRIC SHOCK THAT CAN
CAUSE INJURY OR DEATH: DISCONNECT ALL RE-
MOTE ELECTRIC POWER SUPPLY BEFORE SERVIC-
ING.
There must be an air-break switch.
After installation, the consumer must operate the air conditioner
correctly according to this manual, keep a suitable storage for
maintenance and moving of the air conditioner in the future.
Fuse of indoor unit: T 3.15A 250VAC or T 5A 250VAC. Refer to the
screen printing on the circuit board for the actual parameters,
which must be consistent with the parameters on the screen print-
ing.
For 7 to 12k models, fuse of outdoor unit: T 15A 250VAC or T 20A
250VAC. Refer to the screen printing on the circuit board for the
actual parameters, which must be consistent with the parameters
on the screen printing.
For 14k to 18k models, fuse of outdoor unit: T 20A 250VAC.
For 21 k to 30k models, fuse of outdoor unit: T 30A 250VAC.
Appliances that are permanently connected to fixed wiring, and
have a leakage current that may exceed 10 mA, it is advisable to
include the installation of a residual current device (RCD) having a
rated residual operating current not exceeding 30 mA.