© 2018 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com 8
Rev. Date 040218
Fan Clearance - Universal Mount
WARNING: FANS ARE NOT MEANT TO BE OPERATED IN WINDY CONDITIONS.
The Universal Mount can be used in any application but must always be used in windy
conditions, applications where wind may sometimes be present or where the total clearance
between the mount and the airfoils is greater than 10 feet. The minimum distance of a fan to a
wall or similar obstruction should be no less than 1.5 times the diameter of the fan.
Maximum Angle for Mount (feet)
Slope (in) 0 2/12 4/12 6/12 8/12 10/12
Roof Angle 0 9.5
o
18.4
o
26.6
o
33.7
o
39.8
o
Diameter Recommended Total Drop (Mount to Airfoil) Length (ft)
8 feet 3 3 3 3 4 5
10 feet 3 3 3 4 5 6
12 feet 3 3 3 5 6 7
14 feet 3 3 4 5 7 8
16 feet 3 3 4 6 7 9
18 feet 3 3 5 7 8 N/A*
20 feet 3 4 5 7 9 N/A*
24 feet 3 4 7 9 N/A* N/A*
*Drop lengths longer than 10 feet are not recommended
The drop lengths above are minimum recommendations only, based solely on roof pitch and
fan diameter. Other factors, such as allowing for proper airow into the fan must be evaluated
when determining drop length requirements. In addition, MacroAir strongly recommends that
the fan airfoils must be a minimum of 10 feet (3.05 meters) above the oor. Contact MacroAir for
assistance with fan placement and drop length selection (contact information can be found on
page 74).
The table below shows the clearance
needed from the fan to obstructions such
as lighting, conduit, etc.
Minimum Clearance (Horizontal / Vertical inches):
Airfoil / Drop Length (ft) 2 3 4 5 6 7 8 9 10 11 12
8 feet 7 / 7 7 / 7 7 / 7 7 / 7 8 / 8 8 / 8 9 / 8 11 / 9 13 / 10 N/A** N/A**
10 feet 7 / 7 7 / 7 7 / 8 7 / 8 8 / 8 8 / 9 9 / 9 11 / 10 13 / 11 N/A** N/A**
12 feet 7 / 8 7 / 8 7 / 8 7 / 9 8 / 9 8 / 10 9 / 10 11 / 11 13 / 12 N/A** N/A**
14 feet 7 / 9 7 / 9 7 / 9 7 / 10 8 / 10 8 / 11 9 / 12 11 / 12 13 / 13 N/A** N/A**
16 feet 7 / 10 7 / 10 7 / 11 7 / 11 8 / 12 8 / 12 9 / 13 11 / 14 13 / 15 N/A** N/A**
18 feet 7 / 12 7 / 12 7 / 12 7 / 13 8 / 13 8 / 14 9 / 15 11 / 16 13 / 17 N/A** N/A**
20 feet N/A 7 / 14 7 / 14 7 / 15 8 / 15 8 / 16 9 / 17 11 / 18 13 / 20 N/A** N/A**
24 feet N/A 7 / 19 7 / 19 7 / 20 8 / 21 8 / 22 9 / 23 11 / 24 13 / 26 N/A** N/A**
**Contact MacroAir if you require drop lengths greater than 10 ft

Table of Contents

Other manuals for MacroAir Technologies AirVolution-D 550

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MacroAir Technologies AirVolution-D 550 and is the answer not in the manual?

MacroAir Technologies AirVolution-D 550 Specifications

General IconGeneral
BrandMacroAir Technologies
ModelAirVolution-D 550
CategoryFan
LanguageEnglish

Related product manuals