© 2018 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com 58
Rev. Date 040218
Components:
A - Remote Harness (found in single fan remote enclosure)
B - Terminal Block Connector
Use the schematic above to connect the fan(s) to an emergency stop (i.e. re
alarm system).
Remote Harness
TO FIRE ALARM (CONTROL CIRCUIT)
OPTIONAL
CUSTOMER - SUPPLIED
NORMALLY CLOSED RELAY
N.C.
RELAY
BLUE/WHITE
BLUE
BROWN
BROWN/WHITE
ORANGE
ORANGE/WHITE
Fire Disconnect
Orange Pair
A-02
DO NOT SCALE DRAWING
SHEET 1 OF 1
2/18/2016
5/5/2014
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
RE
EV
UNLESS OTHERWISE SPECIFIED:
Not to Scale
WEIGHT:
REV
DWG. NO.
A
SIZE
TITLE:
MacroAir Technologies
794 S Allen St. San Bernardino, CA 92408
NAME
DATE
COMMENTS:
Q.A.
MFG APPR.
ENG APPR.
CHECKED
DRAWN
FINISH
MATERIAL
INTERPRET GEOMETRIC
TOLERANCING PER:
DIMENSIONS ARE IN INCHES
TOLERANCES:
FRACTIONAL
.010
ANGULAR: MACH
1
BEND
1
TWO PLACE DECIMAL
.01
THREE PLACE DECIMAL
.001
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF
MacroAir TECHNOLOGIES. ANY
REPRODUCTION IN PART OR AS A WHOLE
WITHOUT THE WRITTEN PERMISSION OF
MacroAir TECHNOLOGIES IS
PROHIBITED.
5
4
3
2
1
A
B
6.2 Emergency Disconnect
Schematic
Remote Harness
BLUE/WHITE
BLUE
BROWN
BROWN/WHITE
GREEN
GREEN/WHITE
OPTIONAL
ON - OFF
SWITCH
Fire Disconnect
Green Pair
A-01
DO NOT SCALE DRAWING
SHEET 1 OF 1
2/18/2016
2/18/2016
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
MD
EV
UNLESS OTHERWISE SPECIFIED:
Not to Scale
WEIGHT:
REV
DWG. NO.
A
SIZE
TITLE:
MacroAir Technologies
794 S Allen St. San Bernardino, CA 92408
NAME
DATE
COMMENTS:
Q.A.
MFG APPR.
ENG APPR.
CHECKED
DRAWN
FINISH
MATERIAL
INTERPRET GEOMETRIC
TOLERANCING PER:
DIMENSIONS ARE IN INCHES
TOLERANCES:
FRACTIONAL
.010
ANGULAR: MACH
1
BEND
1
TWO PLACE DECIMAL
.01
THREE PLACE DECIMAL
.001
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF
MacroAir TECHNOLOGIES. ANY
REPRODUCTION IN PART OR AS A WHOLE
WITHOUT THE WRITTEN PERMISSION OF
MacroAir TECHNOLOGIES IS
PROHIBITED.
5
4
3
2
1
6.3 Enable (ON)/Disable (OFF)
Schematic
A -Remote Harness (found in single fan remote enclosure)
B - Terminal Block Connector
C- Green/Green-White pair for remote on/off fan control
Use the schematic above to tie fan(s) to a remote set of supervisory contacts
for fan control. To enable this feature please contact MacroAir Technical
Support. Contact information can be found on page 74.
A
B
C
Fan remote enclosure
Remote Harness
found inside fan
remote enclosure

Table of Contents

Other manuals for MacroAir Technologies AirVolution-D 780

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MacroAir Technologies AirVolution-D 780 and is the answer not in the manual?

MacroAir Technologies AirVolution-D 780 Specifications

General IconGeneral
BrandMacroAir Technologies
ModelAirVolution-D 780
CategoryFan
LanguageEnglish

Related product manuals