8.5.2 Extended Command 0x0306 - Read Terminal Configuration
Like all extended commands, the host initiates this command by calling Command 0x49 - Send
Extended Command Packet (Extended Commands Only), and receives a response as documented
there.
This command is used to read EMV Terminal configuration data. See Extended Command 0x0305 -
Modify Terminal Configuration (MAC) and the Terminal Configuration subsections in Appendix E
EMV Factory Defaults (EMV Only).
Table 8-42 - Request Data for Extended Command 0x0306 - Read Terminal Configuration
Offset
Field Name
Value
0
Slot Number
EMV Terminal Slot Number. Must be 0x01.
1
Operation
0x00 = Read Operation
0x0F = Read All Tags of selected slot
2
Database
Selector
(Contact Only)
0x00 = EMV Contact L2
3..
Tags to Read
Note: Not needed if Operation is 0x0F Read All Tags of selected slot.
FA<len> /* container for generic data */
<tag>
<tag>
Tag DFDF47 cannot be read individually. This tag can only be retrieved using
the ‘Read All Tags’ option.