23 Maintenance Procedures
Do not replace the OEMradiator pressure cap with a
non-standard pressure cap. These will not allow the recovery system
to function properly, causing the engine to overheat and a limited war-
ranty claim to be denied. Your ROXOR authorized dealer can provide
the correct replacement part.
Figure 12. Coolant Overflow Bottle
23.8 Check Engine Oil Level & Leak Check
The oil dipstick is located on the passenger side of the engine.
Engine oil should be checked on a level surface, with engine cold, or
allow time for the oil to drain back into the oil pan before checking
level to prevent overfilling.
Maintenance Interval Check regularly, replace the engine oil every
50 hours, 6 months, 1,500 miles (2,500 Km)
Fluid Spec. API CJ-4 5W/40 (Full Synthetic)
Capacity 7.4 Quarts (7.0 Liters)
1. Position the ROXOR on a flat level surface.
2. Stop the engine and allow time to cool.
3. Unlatch and lift the hood, then place prop rod.
4. Remove the dipstick. Wipe it dry with a clean cloth.
5. Reinstall the dipstick, then remove it and check the oil level.
6. Maintain the oil level in the safe range, between the two notches.
(see Figure 13) Do not overfill.
Figure 13. Oil Level Safe Range
© 2018 Mahindra Vehicle Sales and Service, Inc. All Rights Reserved. 61

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mahindra ROXOR and is the answer not in the manual?

Mahindra ROXOR Specifications

General IconGeneral
BrandMahindra
ModelROXOR
CategoryOffroad Vehicle
LanguageEnglish

Related product manuals