8.2.1 D2 / D3 LED Monitoring Status Combination Scenarios
Table 6 - D2/D3 LED Monitoring Status - Combination Scenarios
Scenario
D2 LED
GREEN
D3 LED
RED
Functions
1 OFF OFF Indicates a DC power failure.
2 OFF Flash When door is closing.
3 ON OFF When operator is on standby.
4 ON Flash
Indicates wrong handing feature activation (if a limit switch is not
released/deactivated within 3.6 sec while door starts to close/open
from the fully open/closed positions).
5 ON ON Indicates a faulty motor centrifugal switch (single-phase only).
6 Flash OFF When door is opening.
7 Flash Flash When timer to close is counting before closing the door.
8 Flash Flash
When door is opening during programming of the run timer or the
mid-stop features. Refer to section 8.3.2, p.25 as reference.