Installation Instructions Section 2
2-8
Part Number 020003315 1/11
PUMP DECK WIRING
The supply cord is equipped with a three prong 5-15P. 
When a Ground Fault Circuit Interrupter (GFCI) is 
required by code, a breaker type protector must be 
used. We do not recommend GFIC outlets as they are 
known for more intermittent nuisance trips than panel 
breakers. To ensure both the safety and proper 
operation of this equipment, be certain that the electrical 
receptacle is a proper design so as to accept this plug, 
ensuring that the carbonator assembly is properly 
grounded. 
If the pump deck is to be installed in an area or 
community whose local codes require permanent wiring, 
the following procedure must be followed.
1. The three wires (white, black and green) must be fed 
through the cable connector and brought into the 
wiring compartment. The cable must be secured into 
the connector.
2. The green wire from the cable must be connected to 
the green screw that attaches to the inside panel of 
the wiring compartment. Be sure to use a ring torque 
terminal for connecting the wire to the screw.
3. The white wire from the cable must be joined to the 
N terminal of the liquid level control board by a 
suitable U.L. listed insulated cable connector.
The black wire from the cable must be joined to the L1 
terminal of the liquid level control board by a suitable 
U.L. listed insulated cable connector.
When using electric appliances, basic precautions
should always be followed, including the following:
a. Read all the instructions before using the 
appliance.
b. To reduce the risk of injury, close 
supervision is necessary when an 
appliance is used near children.
c. Do not contact moving parts.
d. Only use attachments recommended or 
sold by the manufacturer.
e. Do not use outdoors.
f. For a cord-connected appliance, the 
following shall be included:
• Do not unplug by pulling on cord. To 
unplug, grasp the plug, not the cord.
• Unplug from outlet when not in use and 
before servicing or cleaning.
• Do not operate any appliance with a 
damaged cord or plug, or after the 
appliance malfunctions or is dropped or 
damaged in any manner. Contact the 
nearest authorized service facility for 
examination, repair, or electrical or 
mechanical adjustment.
g. For a permanently connected appliance — 
Turn the power switch to the off position 
when the appliance is not in use and before 
servicing or cleaning.
h. For an appliance with a replaceable lamp — 
Always unplug before replacing the lamp. 
Replace the bulb with the same type.
i. For a grounded appliance — Connect to a 
properly grounded outlet only. See 
Grounding Instructions.