Operation Section 3
3-6
Part Number 020003315 1/11
EXTERNAL BRIX MODE
How to Check FRP Brix Externally
If your FRP-250 has a control board with the external brix
check ability you will be able to put the unit into brix mode by
doing the following:
1. Turn the key switch to the “OFF” position.
2. With the key switch still in the “OFF” position, press
and hold the F1 touch pad button for the left side or
F5 for the right while turning the key switch back to
the “ON” position.
F1 = Left Side Brix Check
F5 = Right Side Brix Check
NOTE: The buttons for FRP units without flavor shots
are located in the same area, but are hidden.
3. You can now stop pressing on the F1 or F5 button
and the 4 LEDs around the touch pad area should
now be illuminated. If not illuminated you did not
successfully go into external brix mode and need to
try again, or the FRP unit is not equipped with this
program mode.
In this setting when a corresponding touch pad is pressed
water or syrup will be dispensed for a fixed duration in order
to check your ratios using a brix cup.
4. In this mode you can now check the brix for any water or
syrup valve that corresponds to the board. Use the
illustration in Installation/Brixing or the Control board,
Valve, Touch Pad Matrix to identify the valves and which
board they correspond to. Brixing information can also
be found on the unit, on the right hand side of the control
board cover label. By using this label in combination with
the plumbing label located on the foam front you will be
able to identify each valve, water, and/or syrup
combination.
5. When finished checking the brix return the unit to dispense
mode by turning the keyswitch to the "OFF" position,
waiting till the touch pad LEDs are not illuminated, then turn
the keyswitch back to the "ON" position.
If brix adjustments are needed you will have to remove the
merchandiser to make the mechanical adjustments. Please
see PROGRAM MODE 2 in this section for internal brixing
instructions using the control board and the SECTION 2 /
Brixing Procedure for detailed instructions on brixing the
FRP-250.
CRUSHED OR CUBED DEFAULT
This selectable ice option will allow the unit to always default to
either cube or crushed ice or remain at the last selection. This
only applies to control boards 020000875 Rev 7 and up.
How to set default ice dispense setting
CUBE DEFAULT
1. Power on the unit by plugging in receptacle and holding
the cube button at the same time, cube will flash 2 times.
Unit will now change to cube 10 seconds after crush is
selected and/or used.
CRUSH DEFAULT
2. Power on the unit by plugging in receptacle and holding
the crushed button at the same time, crush will flash 2
times. Unit will now change to crush 10 seconds after
cube is selected and/or used.
LAST SELECTION DEFAULT
3. Power on the unit by plugging in receptacle and holding
cube and crush at the same time, cube and crush will flash
2 times. Unit will now remain in selection of last request.
NOTE: If power is lost to the unit and then powered up
again the unit will retain the last setting and not return to
factory settings.
S1
S3
S2
S4
S5
S7
S6
S8
F1
F2
F4
F3
N1
N3
N2
S12
S10
S11
S9
S16 S14
S15
S13
F5
F6
F8
F7
N4
N6
N5
Right Flavor
Shots
Left Flavor
Shots
FRP-250 WITH FLAVOR SHOTS
Left Carb/
Non-Carb
Right
Carb/Non-
Carb
S1
S3
S2
S4
S5
S7
S6
S8
F1
F2
F4
F3
N1
N3
S12
S10
S11
S9
S16 S14
S15
S13
F5
F6
F8
F7
N4
N6
Right
Hidden
Touchpad
Buttons
Left
Hidden
Touchpad
Buttons
FRP-250 WITHOUT FLAVOR SHOTS
Left Carb/
Non-Carb
Right
Carb/Non-
Carb
Important
If left in external brix mode for longer than 5 minutes it
will automatically time out and return to dispense mode.