5-10 Published 4-09-2021, Control # 364-11
MAINTENANCE AND LUBRICATION RT765E-2 OPERATOR MANUAL
Item
Lube Point
Description
Figure
No.
Approved
Lubricant
Lube
Capacity
Lube Interval Application
Axles
11 Differentials Figure 5-2
GL-5
Extended
Service Interval
Gear Lubricant
6829012964
48 pt
(22.7 l)
Check level every
500 hours or 3
months
Drain and fill every
4000 hours or 2
years
Fill to bottom of hole
in housing on the
steer cylinder side
NOTE: Lube level close enough to the hole to be seen or touched is not sufficient. It must be level with the hole.
When checking lube level, also check and clean housing breathers.
CAUTION: Use of non-approved lubricant may damage components and/or invalidate published lubricant intervals.
CAUTION: If the makeup amount is substantially more than 0.5 pt (0.23 l), check for leaks.
12
Planetary Hubs
and Wheel
Bearings
Figure 5-2
GL-5
Extended
Service Interval
Gear Lubricant
6829012964
8pt
(3.7 l)
Check level every
500 hours or 3
months
Drain and fill every
4000 hours or 2
years
Fill to the bottom of
the level hole in the
housing with the fill
plug and the oil level
mark horizontal.
CAUTION: Use of non-approved lubricant may damage components and/or invalidate published lubricant intervals.

Table of Contents

Other manuals for Manitowoc Grove RT765E-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove RT765E-2 and is the answer not in the manual?

Manitowoc Grove RT765E-2 Specifications

General IconGeneral
BrandManitowoc
ModelGrove RT765E-2
CategoryConstruction Equipment
LanguageEnglish

Related product manuals