150 Part Number: 000015431 Rev01 5/19
SYMPTOM
The alert log indicates a T1, T2, T3, or T4 Fault.
CHECK PROCEDURE
NOTE: Navigate to Menu/Service/Data/Real Time data/
Time & Temperature
NOTE: An open thermistor will display -10°F (-23°C) and a
shorted thermistor displays 400°F (204°C).
Thermistor Test
1. Disconnect the suspect thermistor from the control
board and swap with another thermistor.
A. The symptoms move with the thermistor -
Replace the thermistor.
B. The symptom does not change - Perform control
board test.
Control Board Test
1. Disconnect thermistor from control board - The
display temperature reading, dropping to -10°F
(-23°C) indicates the control board is good.
2. Short thermistor pins - The display temperature
reading, climbing to 400°F (204°C) indicates the
control board is good.

Table of Contents

Other manuals for Manitowoc Indigo NXT Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Indigo NXT Series and is the answer not in the manual?

Manitowoc Indigo NXT Series Specifications

General IconGeneral
ModelIndigo NXT Series
Ice ProductionVaries by model
Ice StorageVaries by model
Energy EfficiencyEnergy Star certified models available
RefrigerantR290 (varies by model)
Cooling SystemAir-cooled or water-cooled (varies by model)
Condenser TypeAir-cooled, Water-cooled, or Remote
Touch DisplayYes, with intuitive interface
ControlCleaning Alerts
FeaturesSelf-cleaning, remote monitoring, energy-saving modes
Power SupplyVaries by model (typically 115V or 208-230V)
Dimensions (H x W x D)Varies by model
WeightVaries by model

Related product manuals