92 Part Number: 000015431 Rev01 5/19
E02 LONG HARVEST
Harvest time exceeds 7 minutes for 3 consecutive harvest
cycles.
Possible Cause Checklist
Improper Installation
“Installation/Visual Inspection Checklist” on page 102
Water System
Water area (evaporator) dirty
Dirty/defective water dump valve
Vent tube not installed on water outlet drain
Water freezing behind evaporator
Plastic extrusions and gaskets not securely mounted to
the evaporator
Clogged water distribution tube
Electrical System
Ice thickness probe out of adjustment
Bin switch closed/defective
Premature harvest
Refrigeration System
Non-Manitowoc components
Improper refrigerant charge
Defective head pressure control valve
Defective harvest valve
TXV flooding (check bulb mounting)
Defective fan cycling control

Table of Contents

Other manuals for Manitowoc Indigo NXT Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Indigo NXT Series and is the answer not in the manual?

Manitowoc Indigo NXT Series Specifications

General IconGeneral
ModelIndigo NXT Series
Ice ProductionVaries by model
Ice StorageVaries by model
Energy EfficiencyEnergy Star certified models available
RefrigerantR290 (varies by model)
Cooling SystemAir-cooled or water-cooled (varies by model)
Condenser TypeAir-cooled, Water-cooled, or Remote
Touch DisplayYes, with intuitive interface
ControlCleaning Alerts
FeaturesSelf-cleaning, remote monitoring, energy-saving modes
Power SupplyVaries by model (typically 115V or 208-230V)
Dimensions (H x W x D)Varies by model
WeightVaries by model

Related product manuals