Part Number: 000015431 Rev01 5/19 67
Single & Twin Evaporator QuietQube® Models
Energized Parts Chart
Ice Making
Sequence of
Operation
Water
Pump
Harvest
Valve(s)
Air
Pumps
Water Inlet
Valve
Water
Dump
Valve
Liquid Line
Solenoid
Valve
Contactor
Refrigeration
Compressor &
Condenser Fan
Motor*
Length of
Time
6. Harvest Off On On Off Off On On
Bin switch
activation
Water Assist
Starts 3.5 minutes in
harvest cycle
Off ** On On On Off** On On
Until curtain switch
activation
7. Automatic
Shut-Off
Off Off Off Off Off Off Off
Until 10 min. delay
expires & all bin
switches re-close
* The condenser fan motor is controlled by a fan cycle control and may cycle on/off.
* The contactor is controlled by a low pressure control and may cycle on/off whenever power is supplied to the condensing unit.
** Water Pump On after 4 minutes - Dump Valve On after 6.5 minutes.

Table of Contents

Other manuals for Manitowoc Indigo NXT Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Indigo NXT Series and is the answer not in the manual?

Manitowoc Indigo NXT Series Specifications

General IconGeneral
ModelIndigo NXT Series
Ice ProductionVaries by model
Ice StorageVaries by model
Energy EfficiencyEnergy Star certified models available
RefrigerantR290 (varies by model)
Cooling SystemAir-cooled or water-cooled (varies by model)
Condenser TypeAir-cooled, Water-cooled, or Remote
Touch DisplayYes, with intuitive interface
ControlCleaning Alerts
FeaturesSelf-cleaning, remote monitoring, energy-saving modes
Power SupplyVaries by model (typically 115V or 208-230V)
Dimensions (H x W x D)Varies by model
WeightVaries by model

Related product manuals