54 Part Number 000007661 11/16
RN1000/RN1400
Self-Contained Air-Cooled & Water-Cooled
NOTE: Ice machines use an auger to remove ice from the
evaporator. Occasional noises (creaks, groans, squeaks, or
pops) are a normal part of the ice making process.
Operation
The ice machine will not start until:
A. The rocker switch is moved to ON.
B. The transport tube shuttle switch is closed.
C. The water reservoir is full of water.
Placing the toggle switch in the ON position starts the
gear motor and refrigeration system. The water level
sensor controls the water inlet valve and water level. The
freeze cycle ends when ice contact opens the transport
tube switch. A 60 minute time delay period initiates.
The ice machine will restart when the ice transport
tube switch closes and the 60 minute time delay period
expires.
Flush Cycle
The ice machine will automatically flush the evaporator.
The refrigeration system will shut down and the gear
motor will continue to run. After the flush is complete,
the machine will refill and start the refrigeration system
without a time delay.