Self-Propelled Scissor Lift
8 Error Codes (Only for Type B Platform Controller)
If an error occurs on a machine equipped with a type B platform controller, an error code will appear
on the display of the platform controller.
More information about these error codes, their possible cause and solutions can be found in the table
below.
Electronic Control
Module (ECM) error
Replace the Electronic Control
Module (ECM)
ECM/Platform
controller
communication error
Cable or platform
controller failure
Find the fault of the cable and/or
platform controller
Platform DIP switch
error
DIP switch setting is not
correct
Change the DIP switch setting
Check the Up/Down switch on the
ground control panel
Pothole guard switch
failure or pothole guard
coupling blocked
Check the pothole guard switch
and/or remove obstacle
Limit switch failure or
limit switch wire broken
Check the limit switch and/or check
limit switch wire
Turning left switch
error
Turning left switch
failure
Check the turning left switch on the
control handle
Turning right switch
error
Turning right switch
failure
Check the turning right switch on
the control handle
Function enable
switch error
Function enable switch
failure
Check the function enable switch
on the control handle
Platform control
handle error
Control handle not in
median
Recalibrate control handle
(potentiometer)
Coil failure or coil
disconnected
Check forward valve coil and wiring
Backward valve coil
error
Coil failure or coil
disconnected
Check backward valve coil and
wiring
Coil failure or coil
disconnected
Check raising valve coil and wiring
Lowering valve coil
error
Coil failure or coil
disconnected
Check lowering valve coil and
wiring
Right turn valve coil
error
Coil failure or coil
disconnected
Check right turn valve coil and
wiring
Left turn valve coil
error
Coil failure or coil
disconnected
Check left turn valve coil and wiring