Installation manual / Manusa
DTCXSO01EN-V10
76.4 Setting up reduced opening or pharmacy position – bravo operator only
6.3 Selecting language
Press (2) repeatedly until F9 appears. Then press (3).
The current language is shown on the display, represented by a number between 0 and 7:
Press (2) repeatedly until the desired language’s number appears. Then press (3) to confirm.
6.4 Setting up Reduced Opening or Pharmacy Position – Bravo operator only
To access settings that depend on the opening mode, proceed as follows: Press (2) repeatedly until FA appears.
Then press (3).
The current setting is shown on the display, represented by a number between 0 and 6:
To select the desired mode:
Press (2) repeatedly until the desired setting appears. Then press (3) to confirm.
Once the mode has been set, it can be activated using either the remote control or the Optima program switch.
Remote control (optional):
To complete the setting using the remote control, just press
Optima program switch:
Completion of the setting using the Optima program switch depends on which mode is being programmed:
- If Pharmacy mode has been set (Bravo operator only): Press and hold (2) and simultaneously press
- If Reduced Opening mode has been set: Press and hold (2) and simultaneously press
To deactivate both Pharmacy and Reduced Opening modes, press another operating mode, whether using the remote
control or the program switch.
Note: Settings with VISIO+ operator: With VISIO+, when Reduced Opening has been set, it is activated.
Press (2) repeatedly until F8 appears. Then press (3).
Once set, check correct operation of safety elements: photocells, radars, etc.
Note: For Visio and Bravo operators, ensure the leaves are closed before starting the self-adjustment procedure.
• 0 Spanish
• 1 French
• 2 English
• 3 German
• 4 Italian
• 5 Portuguese
• 6 Dutch
• 7 Catalan
• 0 Pharmacy Position
• 1 Reduced Opening 1
• 2 Reduced Opening 2
• 3 Reduced Opening 3
• 4 Reduced Opening 4
• 5 Pharmacy Position and Reduced Opening deleted
• 6 Reserved
• 1 Reduced Opening 1 to 20 %
• 2 Reduced Opening 2 to 40 %
• 3 Reduced Opening 3 to 60 %
• 4 Reduced Opening 4 to 80 %