AH Opening width
PL = (AH-Dt)/2 Clear width
AT = PL/2+Dt Overall operator width
AM = PL/2+Sp Sliding leaf width
AF = (AH-PL)/2 Fixed leaf width
1.3
1.4.1
1.4.2
1.4
S2right
S2left
1.4.1
i
S1* Safety distances depending on Frame:
i
S2*
Safety distance depends on S as follows:
For D20,T20,F20,R20,T35,D35 S1 = 0mm
For E20 S1 = 50mm
For I30 S1 = 55mm
For C44 S1 = 105mm
For S44 S1 = 105mm
If S <250 S2 = 200 mm
If S ≥250 S2 = 500 mm