LOCAL
Save LCD
Setting
Display
ON/OFF
ttBWWi
Dim
Use Knob to Adjust Contrast
Medium 1
Medium
2
vv.w.w
Bright
I
C0059
Fig.
3-1-27
Display adjust menu
Hardware information
To obtain
a
description of
the instrument hardware, press [Hardware Status] and the
following information is displayed:
Instrument type
(e.g.
2041
)
Serial no. (e.g. 1543256/045)
Options fitted (e.g.
SECOND LF OSC.)
Attenuator type and serial number.
For attenuator calibration information,
refer to the
Service
Manual.
Software information
To obtain
a
description of
the instrument software, press
[Software Status
]
and
the
following
information is displayed:
Software version
number e.g. 2.008
Part number e.g.
44533-366
GPIB address
e.g. 07
External trigger
The external trigger facility allows
the rear panel TRIGGER input to be set up so as to
initiate
a defined change in the generator setting. To define the function press [External Trigger
].
The display changes to show the External Trigger
Selection Menu which has the following
options:
[Sweep Start
]
[Sweep Step]
[Send Seq Tones]
[Recall
Up]
[Recall Down]
[No Ext. Trigger]
Starts the external sweep.
Goes to next step of external sweep.
Equivalent to [Send Tones] on
main menu.
Recall
next store.
Recall previous store.
Trigger ignored (default).
A switch closure or voltage
transition from +5 V to 0 V applied to the rear panel socket
initiates the trigger action.