MGT 240M–1200M
SYSTEM 14 – DEMAND
3” NXT2 SERIES METERED
MODEL NO:
SERIAL NO:
DATE INSTALLED:
DEALER:
COMPLETE FOR FUTURE REFERENCE:
Standard Photograph
Equipment appearance may differ.
Triple system shown with skid
mount option.
COMMERCIAL WATER CONDITIONER
INSTALLATION, OPERATION, AND MAINTENANCE MANUAL
8-636

Questions and Answers

  • M
    Megan ArmstrongSep 4, 2025
    What does 'Optical Sensor Undesired change detected by the Optical Sensor' mean on my MARLO MGT 240?
    • D
      David YoderSep 4, 2025
      If your MARLO Water Dispenser displays 'Optical Sensor Undesired change detected by the Optical Sensor', it means that the motor is off but additional encoder pulses are detected. To resolve this, trigger a manual regeneration.
  • M
    monicabeanSep 2, 2025
    What does 'Over-Current Motor Over-Current is Detected' mean on my MARLO Water Dispenser?
    • M
      Mercedes ChambersSep 2, 2025
      If your MARLO Water Dispenser displays 'Over-Current Motor Over-Current is Detected', it indicates that the motor current exceeds thresholds. To resolve this, trigger a manual regeneration.
  • D
    Daniel PayneAug 31, 2025
    What does 'Motor Run-On No CAM Switch Change Detected' mean on my MARLO MGT 240?
    • K
      Kyle ChapmanAug 31, 2025
      If your MARLO Water Dispenser shows 'Motor Run-On No CAM Switch Change Detected', it means that the motor is on but no encoder pulses are detected or CAM Switches change state within a given duration. Verify correct valve type is chosen and trigger a manual regeneration.
  • S
    samanthahamptonAug 29, 2025
    Why is my MARLO MGT 240 softener failing to draw brine?
    • K
      Kimberly PhillipsAug 29, 2025
      If your MARLO Water Dispenser softener fails to draw brine, it could be due to a plugged drain line flow control (clean it), a plugged injector (clean it), a plugged injector screen (clean the screen), line pressure being too low (increase line pressure to 20 P.S.I), an internal control leak (change seals, spacers, and piston assembly), or the service adapter not cycling (check drive motor and switches).
  • D
    david63Aug 27, 2025
    What causes excessive water in the brine tank of my MARLO MGT 240?
    • M
      Melissa WrightAug 28, 2025
      Excessive water in the brine tank of your MARLO Water Dispenser can be caused by a plugged drain line flow control (clean flow control), a plugged injector system (clean injector and screen), the timer not cycling (replace timer), foreign material in the brine valve (replace brine valve seat and clean valve), or foreign material in the brine line flow control (clean brine line flow control).
  • K
    Kenneth CarterAug 26, 2025
    Why does the drain of my MARLO MGT 240 Water Dispenser flow continuously?
    • K
      Kiara JohnsonAug 27, 2025
      If the drain of your MARLO Water Dispenser flows continuously, it could be due to several reasons: the valve is not programming correctly (check timer program and positioning of control, replace power head assembly if not positioning properly), foreign material in the control (remove power head assembly and inspect bore, remove foreign material and check control in various regeneration positions), or an internal control leak (replace seals and piston assembly).
  • J
    Jenna PaulAug 25, 2025
    What does 'Flow Meter Error Continuous Flow Detected' mean on my MARLO Water Dispenser?
    • R
      Randall FritzAug 25, 2025
      If your MARLO Water Dispenser shows a 'Flow Meter Error Continuous Flow Detected', it means that the flow has exceeded the specified threshold for a specific duration. To fix this, trigger a manual regeneration.