Specifications
appendix e
SPECIFICATIONS
Physical
Length........................................................................................................................................... 330 mm (13.0 in.)
Width ............................................................................................................................................ 384 mm (15.1 in.)
Maximum height (full tilt)............................................................................................................ 536 mm (21.1 in.)
Approximate weight........................................................................................................................... 21 kg (46 lbs)
Compatible lamps
Osram HSD 250...................................................................................................2000 hr., 6000K, 250 W, 68 lm/W
Philips MSD 250/2 ..............................................................................................2000 hr., 6500K, 250 W, 68 lm/W
Philips MSD 200 .................................................................................................2000 hr., 5600K, 200 W, 66 lm/W
Performance
Light output (MSD 250/2, no effects applied).......................................................................................4765 lumens
Thermal
Maximum ambient temperature (T
a
) ................................................................................................. 40° C (104° F)
Maximum lamp-socket temperature ............................................................................................... 150° C (302° F)
Maximum shell surface temperature ................................................................................................ 90° C (194° F)
Control and programming
Data pin-out............................................................................................... pin 1 shield, pin 2 cold (-), pin 3 hot (+)
Receiver.................................................................................................................................. Opto-isolated RS-485
Protocols................................................................................................. USITT DMX-512 (1990), Martin RS-485
DMX Channels.................................................................................................................................................9 - 13
Connections
AC input............................................................................................................................ 3-prong IEC male socket
Data input ................................................................................................................locking 3-pin XLR male socket
Data output ...........................................................................................................locking 3-pin XLR female socket
Fuses
Fuse 01 (primary) .............................................................................................................. 6.3 A / 250 V time-delay
Fuse F601 .........................................................................................................................5.0 A / 250 V time-delay
Fuse F602 ..........................................................................................................................4.0 A / 250 V time-delay
Fuse F603 ...................................................................................................................... 0.315 A / 250 V time-delay
Design standards
Canadian safety..........................................................................................................................CSA C22.2 NO 166
EU EMC.........................................................................................................................EN 50 081-1, EN 50 082-1
EU safety .....................................................................................................................EN 60598-1, EN 60598-2-17
US safety........................................................................................................................................... ANSI/UL 1573
Installation
Orientation........................................................................................................................................................... any
Minimum distance to combustible materials...................................................................................... 0.4 m (16 in.)
Minimum distance to illuminated surfaces......................................................................................... 0.4 m (16 in.)
Minimum clearance around fans and air vents...................................................................................... 0.1 m (4 in.)