30 MAC Encore Performance User Guide
* Menus marked * are available only when the fixture is connected to mains power. All other menus are available in mains- and
battery-powered operation.
SERVICE
ERROR LIST Empty or up to 20 errors Display any errors in memory
FAN CLEAN ON/OFF Activate fan cleaning
PT FEEDBACK
ON
Enable pan/tilt position feedback
systems
OFF Disable pan/tilt position feedback
ADJUST
PA N / T I LT AT E N D
STOP
STEP 1
To adjust, move head to P/T adjustment
position, then press Enter
STEP 2
To adjust, move head to P/T adjustment
position again, then press Enter
CALIBRATION
DIMMER ...
FRAMING ROT
0.00 ...+/- xx%
Scroll through effects. Define home
position for each effect
PAN 0.00 ...+/- xx% Define pan home position
TILT 0.00 ...+/- xx% Define tilt home position
LOAD DEFAULTS LOAD Load factory default calibration settings
SAVE DEFAULTS SAVE
Replace factory default calibration settings
with current calibration settings
USB
NO DEVICE
No USB device present or no firmware on
USB device
UPDATING FILES
Fixture updating internal memory from
USB device
AVAILABLE
FIRMWARE
XX.XX.XX ...
XX.XX.XX
Select firmware from versions stored in
internal memory. Scroll to select version,
then press Enter and confirm your choice
to update
Menu level 1 Menu level 2 Menu level 3 Menu level 4 Notes (Default settings in bold print)
Table 3: Control menus