Service and display messages 35
The fixture reports a calibration error if valid calibration data is not detected in EEPROM. The fixture may be
unable to read/write calibration data to EEPROM.
UEPT
UPL ERR PAN/TILT
Could not upload new pan/tilt system firmware during a firmware upload. Error cleared when
new firmware is uploaded successfully or power is cycled off and on.
UEZF
UPL ERR Z/F
Could not upload new zoom/focus system firmware during a firmware upload. Error cleared
when new firmware is uploaded successfully or power is cycled off and on.
UITC
UI TEMP CUT OFF
User interface (LCD display and control panel) PCB temperature cutoff activated.
UITE
UI TEMP SEN ERR
User interface (LCD display and control panel) PCB temperature sensor error.
VOLO
VOLT AT NODE LOW
Low voltage detected in node PCBA.
YEER
TELLOW ERROR
Yellow flag position error.
ZFTC
ZF TEMP CUT OFF
Zoom/focus effect temperature cutoff activated.
ZFTE
ZF TEMP SEN ERR
Zoom/focus effect temperature sensor error.
ZOER
ZOOM ERROR
Zoom position electrical indexing system timeout.
Short code
Long message and explanation
Table 5: Error messages