EasyManuals Logo

Mastech MS8264 User Manual

Mastech MS8264
15 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #12 background imageLoading...
Page #12 background image
20V 10mV
200V 100mV
1000
V
1V ± (0.8% of rdg +2 digits)
Input impedance: 10M (
Max. input voltage: 250Vdc or ac rms for 200mV range and 1000Vdc or 750V ac rms for other ranges,
4.2.2 AC Voltage
Range Resoluti
on
Accuracy
2V 1mV
± (0.8% of rdg +3 digits)20V 10mV
200V 100mV
750V 1V ± (1.2% of rdg +3 digits)
Input impedance: 10M (
Max. input voltage: 250Vdc or ac rms for 200mV range and 1000Vdc or 750V ac rms for other ranges,
Frequency Range: 40Hz-200Hz for 750V range, 40Hz-400Hz for other ranges.
Response: Average, calibrated in rms of sine wave
4.2.3 Frequency
Range Resoluti
on
Accuracy
20kHz 10 Hz ± (1.5% of rdg+5 digits)
Overload protection: 380V dc or 380V ac rms.
Input Voltage range: 200mV-10V ac rms
4.2.4 Resistance
Rang
e
Resolut
ion
Accuracy
200 ( 0.1 ( ± (0.8% of rdg+3 digits)
2k ( 1 (
± (0.8% of rdg+1 digit)
20k ( 10 (
200k ( 100 (
2M ( 1k (
20M ( 10k ( ± (1.0% of rdg+2 digits)
200M ( 0.1M ( ± [5.0% of (rdg-10digits) +10
digits]
Overload protection: 380V dc or 380Vac rms.
Open Circuit Voltage: Less than 700mV.
4.2.5 Diode
Rang
e
Resoluti
on
Function
1mV Display read approx.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mastech MS8264 and is the answer not in the manual?

Mastech MS8264 Specifications

General IconGeneral
BrandMastech
ModelMS8264
CategoryMultimeter