LP CYLINDER VALVE REQUIREMENT:
• Purchase LP cylinders only with these required measurements: 12” (30.5 cm)
(diameter) x 18” (45.7 cm) (tall) with 20 lb. (9.1 kg) capacity maximum.
• Q.C.C. Type 1 outlet compatible with regulator or appliance.
• Safety relief valve.
• UL-listed Overfill Protection Device (OPD). This OPD safety feature is identified
by a unique triangular hand wheel. Use only tanks equipped with this type of valve.
• LP cylinder must be arranged for vapor withdrawal. The LP cylinder must
be constructed and marked in accordance with the Specifications for
LP-Gas Cylinders of the U.S. Department of Transportation (D.O.T.) or
the National Standard of Canada CAN/CSA – B339, Cylinder, Spheres
and Tubes for Transportation of Dangerous Goods; and Commission of
Dangerous Goods; as applicable.
• The LP cylinder must include a collar to protect the cylinder valve.
• If the outdoor cooking gas appliance is not in use, the gas must be
turned o at the supply cylinder(s).
• The LP cylinder must be stored outdoors out of the reach of children
and MUST NOT be stored in a building, garage, shed, breezeway, or any
other enclosed space.
• Storage of an outdoor cooking gas appliance indoors is permissible
ONLY if the cylinder is disconnected and removed from the outdoor
cooking gas appliance.
• The cylinder should ALWAYS be put in an upright position.
OPD Hand Wheel
LP Tank Valve
Safety Cap
Retainer Strap
DANGER:
• DO NOT connect this appliance to an existing #510 POL cylinder valve with left-hand threads.
The Type 1 valve can be identified with the large external threads on the valve outlet.
• DO NOT connect to a propane cylinder exceeding its capacity.
• DO NOT connect to a cylinder that uses any other type of valve connection device.
• Never store a spare LP gas cylinder under or near your grill. This could cause pressure to be expelled
through the vapor relief valve resulting in fire, explosion, or severe personal injury, including death.
• Keep the ventilation opening(s) of the LP gas cylinder enclosure free and clear from obstructions
and debris.
• DO NOT insert any foreign objects into the valve outlet. Damage to the valve outlet could result.
A damaged valve outlet can cause a leak, possibly resulting in explosions, fire, severe bodily harm,
or death.