OPERATING INSTRUCTIONS
Relative mode is available in all functions except frequency and duty
cycle functions.
Selecting relative mode causes the meter to store the present
reading as a reference for subsequent measurements.
Using Relative Mode
DIODE AND CONTINUITY
RANGE INTRODUCTION TEST CONDITION
The approx. forward
voltage drop of the
diode will be displayed.
Open Circuit Voltage:
about 1.5 V
Overload Protection:
300 V DC/AC
The built-in buzzer will
sound if the resistance
is less than about 50 Ω.
The buzzer will not
sound if the resistance
is more than 120 Ω.
Open Circuit Voltage:
about 0.45 V
Overload Protection:
300 V DC/AC
model no. 052-1899-2 | contact us 1-800-689-9928
19
TECHNICAL SPECIFICATIONS