ChargeMaster Plus 24/80-2, 24/110-2 – User and Installation Manual
Bulk voltage (@ 25°C); see section
5.4
Minimum time of the Bulk phase
since Start bulk timer
Battery voltage trigger point to start
the bulk timer
Maximum time of the Bulk phase
since Start bulk timer
Absorption voltage (@ 25°C); see
section 5.4
Return amps. If the charge current
drops below this level, the charger
switches from the Absorption to the
Float stage (% of I
max
)
Float voltage (@ 25°C); see section
5.4
Return to bulk voltage; If the battery
voltage stays below this level for at
least the Return to bulk delay time,
the charger will start the Bulk stage
Return to bulk delay time, see Return
to bulk voltage
Selection of the MasterShunt to
which output 1 of the ChargeMaster
Plus is connected
Not selected,
MSH + Product Name
Read-only information about ChargeMaster Plus
version
Button to reset the ChargeMaster
Plus to default settings (requires
installer rights)
Parameters marked with a are not available in CZone